freehire launches on Product Hunt on 26 August.

Follow →

Engineer – Mechanical Design – Data Centre

Summary

Designs and optimizes cooling systems for data centres, ensuring reliability and energy efficiency across the asset lifecycle.

The Engineer – Mechanical Design – Data Centre is a full-time role based in Singapore or Indonesia (Batam).

The role reports to the Senior Manager – Data Centre.

Overview

The Engineer – Mechanical Design is responsible for the design, technical governance and engineering support of mechanical infrastructure across the company’s data centre portfolio. The role supports the full asset lifecycle – from concept design and construction through commissioning, operations, upgrades and capacity expansion – to ensure facilities meet the highest standards of availability, reliability, scalability, sustainability and operational efficiency.

Working closely with internal design, construction, operations and commissioning teams, the Engineer – Mechanical Design will develop and review mechanical engineering solutions that support mission-critical environments while ensuring compliance with company design standards and industry best practices.

Key responsibilities

  • Develop, review and approve mechanical system designs for new data centre developments and major facility expansions.
  • Prepare and review engineering calculations, technical specifications, equipment schedules and design documentation.
  • Design and optimise mission-critical cooling systems, including:
  • Chilled water plants.
  • Air-cooled and water-cooled systems.
  • CRAH/CRAC systems.
  • In-row and overhead cooling solutions.
  • Cooling towers.
  • Pumping systems.
  • Mechanical piping networks.
  • Ventilation and pressurisation systems.
  • Perform cooling load calculations, hydraulic analyses and equipment sizing.
  • Evaluate innovative cooling technologies, including liquid cooling solutions for high-density AI and HPC deployments.
  • Develop standardised design guidelines and engineering specifications across the data centre portfolio.

Design Review & Technical Governance

  • Review consultant and contractor designs to ensure compliance with company standards, project requirements and applicable codes.
  • Participate in design reviews, HAZOP, constructability reviews, value engineering and technical risk assessments.
  • Ensure mechanical designs support maintainability, operational resilience, energy efficiency and future scalability.
  • Manage technical deviations and engineering change requests.

Project Delivery

  • Support project teams throughout design, procurement, construction, commissioning and handover.
  • Review technical submissions, vendor proposals, equipment selections and shop drawings.
  • Participate in Factory Acceptance Tests (FAT), Site Acceptance Tests (SAT), Integrated Systems Testing (IST) and commissioning activities.

Operations & Asset Lifecycle Support

  • Provide engineering support for operating data centres.
  • Evaluate plant performance and recommend improvements to reliability, capacity and energy efficiency.
  • Support root cause analysis (RCA) of mechanical failures and develop corrective actions.
  • Plan infrastructure upgrades, equipment replacement and capacity expansion while maintaining operational continuity.
  • Collaborate with operations teams to optimise preventive maintenance strategies and improve asset reliability.

Sustainability & Innovation

  • Support initiatives to improve Power Usage Effectiveness (PUE), Water Usage Effectiveness (WUE), and overall facility sustainability.
  • Evaluate emerging cooling technologies, energy-efficient equipment and digital engineering solutions.
  • Promote standardisation, automation and continuous improvement across the mechanical engineering function.

Qualifications & experience

  • Bachelor’s Degree in Mechanical Engineering or equivalent.
  • Minimum 5 years of relevant experience in mechanical design of mission-critical facilities, with significant exposure to hyperscale or enterprise data centres.
  • Experience working for a data centre owner/operator, engineering consultancy or EPC contractor delivering large-scale mission-critical projects.
  • Professional Engineer (PE), Chartered Engineer (CEng) or equivalent professional registration is preferred.
  • Strong knowledge of mission-critical HVAC systems and precision cooling technologies.
  • Experience in chilled water system design, hydraulic balancing and pumping system optimisation.
  • Knowledge of data centre cooling strategies, including hotaisle/cold aisle containment, free cooling, economisation, liquid cooling, high-density rack cooling.
  • Understanding of mechanical redundancy philosophies (N, N+1, 2N, 2N+1).
  • Familiarity with ASHRAE Thermal Guidelines, SMACNA, NFPA, ASME and relevant local building codes.
  • Experience with CFD analysis and airflow optimisation is advantageous.
  • Proficiency in AutoCAD, Revit MEP, Navisworks and BIM coordination.
  • Experience with engineering software such as HAP, IES VE or equivalent.
  • Understanding of commissioning methodologies and integrated systems testing for mission-critical facilities.
  • Familiarity with Building Management Systems (BMS) and Data Centre Infrastructure Management (DCIM) platforms is desirable.

See also

Tailor your CV for this role?

We couldn't check your fit for this role — add a CV to your profile to see it next time.

A new version of freehire is available